PRODUCTS

Display instrument series

Water level indicator

CONSULT NOW
technical parameter
Mounting hole size: 111 x 111mm.
1, water level range: the same as the sensor (10m, 20m, 40m, 80m, etc.) 
2, resolution: same as sensor (1cm, 1mm, etc.)
3, measurement accuracy: the same as the sensor, that is, + 0.1% x range + 1cm (or 1mm)∑.
4, display mode: 6 bit plus 2 bit LED display. The 6 is absolute wa✘ter level (4 bit relative water level, +6 bit elevation), showλing (red), word height 0.56". 2 for communication station number or as other symbolγs (green), word height 0.3".
5, the connection between sensor and display: multi-core cable (14~20 core).
6, input code system (sensor output code): cyclic code (Ge Leima) or other code system (αto be customized).
7, the distance between sensor and display: up to 2km.
8, data remote transmission mode (optional):
1) RS-485 (type XZ-1A), using a pair of twisted pair transmissαion networking. Data remote transmission distance: 1.2km.
RS-485 port communication protocol: 1) MOD-WS1 (MODBUS); 2) SDI-12.
2) 4~20mA current loop mode (type XZ-1B), with a pair of wire transmissi≤on.
The above data does not contain elevation values
9 、 current loop: resolution: same as sensor; nonlinearity: MAX + 0.012%; maximu♣m error: + 0.15%
10, manual preset function
1) lower limit preset: zero at the factory. (4, without elevation)
2) upper limit preset: the maximum opening value at the factor•y. (4, without elevation)
3) preset preset: the maximum opening value at the factory. (4, without elevation)
4) altitude preset: zero at the factory. (6 digits)
5) range (type XZ-1B only): range (4 bit, without altitude)
6) communication station number preset: usually set to 01 at the factory.
11. Alarm and control function
Alarm control signal: relay contact. Contact capacity: 1A"24VDC, 0.5A125VAC.
When it is greater than or equal to the upper, middle and loweσr or lower limits, the relay contacts attract, and® the sound and light alarm (the decimal point flashes in the data area). The∞ duration of the sound alarm is about 10 seconds. Only relay action in the middle limit.
12, display and sensor coupling: photoelectric isolation
13, work mode: continuous work.
14, the display single chip microcomputer plus Watchdog, in order to prevent the operatio↑n of the accident.
15, working environment temperature: 0 ~ +50 centigrade, relative humidity: 85% (+25).¥
16, power supply: 120VAC~ 264VAC, 47~440Hz. Power consumption: <5W. Fuse 2A.
17, size: 120 x 120 x 120mm.