PRODUCTS

Display instrument series

Gate opening tester

CONSULT NOW
technical parameter
1. gate opening range: the same as the sensor (10m, 20m₩, 40m, 80m, etc.).
2. resolution: same as sensor (1cm, 1mm, etc.).
3. measurement accuracy: the same as the sensor, that is, + 0.÷1% x range + 1cm (or 1mm).
4. display range: 99.99m or 999.9cm
5. display mode: 2 x 4 bit LED display. The top 4 is gate opening value, sh✘owing (red) and word height 0.8". The lower limit of 4 displa™y (green), 0.8 characters".
6. connection between sensor and display: multi core cable (14~20 core).
7. input code (sensor output code): cyclic code (Ge Leima) or other code system (to be custo÷mized).
8. cable distance between sensor and display: up to 2km.
9. data remote transmission mode (optional):
1) RS-485 (type XZ-9A), using a pair of twisted pair transmission networking.
Data remote transmission distance: 1.2km.
RS-485 port communication protocol: 1) MOD-WS1 (MODBUS); 2) SDI-12.
2) 4~20mA current loop mode (type XZ-9B), with a pair of wire transmission.
10. current loop: resolution: same as sensor; nonlinearity: MAX + 0.012%;← maximum error: + 0.15%
11. manual preset function
1) limit (gate lift limit) preset: when the factory is aΩn arbitrary value.
2) upper limit preset: the maximum opening value at the facto↓ry.
3) lower limit preset: zero at the factory.
4) block numerical preset
5) communication station number preset: usually seΩt to 01 at the factory.
12. alarm and control function
Alarm control signal: relay contact. Contact capacity: 1A24VDC, 0.5A125VAC.
When the value is greater than or equal to the upper limit, less than or equal to the lower limit >value, the relay contacts attract, and the sound and light alarm (the decimal point flicker  in the data area). The duration of the sound alarm is about 10 seco≤nds. Only relay action in the middle limit.
When the preset limit, if higher than the gate position, the alarm is greater thanλ or equal to the limit value; when the preset is lower than the gate position≠ at that time, the alarm is less than or equal to the limit valu¶e
13. display and sensor coupling: photoelectric isolation
14. working environment temperature: 0 ~ +50 centigrade, relative humidity: 85% ≤(+25).
15. power supply: 120VAC~ 264VAC, 47~440Hz. Power consumption: <5W. Fuse →2A.
16. outline size: 120 x 120 x 120mm.
Mounting hole size: 111 x 111mm.